Nitrogen Gas Generator for Gas Chromatography (GC)
Ultra-High-Purity Nitrogen Gas Generator for Gas Chromatography (GC)
Athena Instruments introduces the Nitrogen Gas Generator for Gas Chromatography (GC), a high-precision, laboratory-grade nitrogen generation system engineered for the consistent supply of ultra-high purity (UHP Grade) nitrogen gas used in Gas Chromatography applications. Built with advanced PSA (Pressure Swing Adsorption) technology and equipped with multi-stage filtration, our nitrogen generators ensure stable pressure, consistent flow, and contamination-free gas output essential for accurate GC analysis across research, petrochemicals, pharmaceuticals, environmental testing, and industrial laboratories.
Designed to meet the growing demand for cylinder-free nitrogen, this system provides a reliable, safe, and cost-efficient alternative to traditional gas cylinders. With purity levels up to 99.9995%, the Athena Nitrogen Gas Generator is optimized for sensitive GC detectors including FID, FPD, NPD, ECD, TCD, AED, ELSD, ATD, and autosampler systems.
Each unit is tested under rigorous performance criteria and manufactured in compliance with CE, ISO 9001:2015, and FDA standards to ensure long-term reliability and analytical accuracy.
Key Features :
- High-Purity Nitrogen Output: Delivers nitrogen with 99.999% – 99.9995% purity, ensuring stable detector baselines and high reproducibility for chromatographic analysis.
- Advanced PSA Technology: Dual-column PSA system with fully regenerative carbon molecular sieve beds ensures consistent nitrogen purity and long operational lifespan.
- Consistent Pressure & Flow Delivery: Provides output pressure up to 7 kg/cm2, supporting multi-GC setups while maintaining uniform flow rates under varying laboratory loads.
- Integrated Multi-Stage Filtration: Equipped with ultrafine dust, moisture, oil, and hydrocarbon removal filters, including 0.01 µm filtration, ensuring gas-tight integrity and contaminant-free output.
- Compact & Robust Design: Space-efficient system constructed with high-grade components, optimized for continuous performance with minimal maintenance.
Applications
Microbiology & Culture Growth
Pharma & QC Testing
Food & Water Testing
Research & Academic Labs
Clinical & Diagnostic Labs
Product Models & Specifications
|
Model Name |
Capacity | Chamber Size (cm) | Power | Shelves |
|---|---|---|---|---|
|
ATBAI-1 S/G |
45 L |
35 × 35 × 35 |
300 W |
2 |
|
ATBAI-2 S/G |
90 L |
45 × 45 × 45 |
400 W |
3 |
|
ATBAI-3 S/G |
120 L |
45 × 45 × 60 |
750 W |
3 |
|
ATBAI-4 S/G |
220 L |
60 × 60 × 60 |
1000 W |
3 |
|
ATBAI-5 S/G |
250 L |
60 × 45 × 90 |
1250 W |
3 |
|
ATBAI-6 S/G |
325 L |
60 × 60 × 90 |
1500 W |
4 |
Analytical & Industrial Use
- Petrochemical and refinery labs
- Environmental monitoring agencies
- Pharmaceutical R&D, QC
- Material science & advanced research
Additional Technical Highlights
Capacity Range
100 ml/min to 10,000 ml/min (custom options available)
Purity
99.999% – 99.9995%
Oxygen Content
< 5 ppm
Moisture Content
< 2 ppm
Particle Filtration
0.01 µm
Output Pressure
Upto 7 kg/cm2
Technology
PSA with fully regenerative columns
Electrical Supply
220V AC, 1-phase, 50 Hz
Noise Level
55 – 60 dB
Why Choose Athena’s Bacteriological Incubators?
Precision Engineered
Designed specifically for GC applications requiring stable, high-purity nitrogen.
Continuous & Reliable Supply
Ensures uninterrupted nitrogen availability for long-duration testing.
Customizable Configurations
Available in multiple flows, pressures, and integration options.
Global Support
Athena provides technical assistance through video, phone, or on-site support for institutional installations.
Cylinder-Free Operation
Eliminates handling risks, storage issues, and recurring cylinder costs.
Cost-Efficient
Significant long-term savings versus cylinder-based systems.
1-Year Manufacturer’s Warranty
Covers manufacturing defects and performance reliability.
Trusted Performance, Certified Quality
Need help finding a solution?
Nitrogen Gas Generator for Gas Chromatography (GC)
Ultra-High-Purity Nitrogen Gas Generator for Gas Chromatography (GC)
Athena Instruments introduces the Nitrogen Gas Generator for Gas Chromatography (GC), a high-precision, laboratory-grade nitrogen generation system engineered for the consistent supply of ultra-high purity (UHP Grade) nitrogen gas used in Gas Chromatography applications. Built with advanced PSA (Pressure Swing Adsorption) technology and equipped with multi-stage filtration, our nitrogen generators ensure stable pressure, consistent flow, and contamination-free gas output essential for accurate GC analysis across research, petrochemicals, pharmaceuticals, environmental testing, and industrial laboratories.
Designed to meet the growing demand for cylinder-free nitrogen, this system provides a reliable, safe, and cost-efficient alternative to traditional gas cylinders. With purity levels up to 99.9995%, the Athena Nitrogen Gas Generator is optimized for sensitive GC detectors including FID, FPD, NPD, ECD, TCD, AED, ELSD, ATD, and autosampler systems.
Each unit is tested under rigorous performance criteria and manufactured in compliance with CE, ISO 9001:2015, and FDA standards to ensure long-term reliability and analytical accuracy.
Key Features :
- High-Purity Nitrogen Output: Delivers nitrogen with 99.999% – 99.9995% purity, ensuring stable detector baselines and high reproducibility for chromatographic analysis.
- Advanced PSA Technology: Dual-column PSA system with fully regenerative carbon molecular sieve beds ensures consistent nitrogen purity and long operational lifespan.
- Consistent Pressure & Flow Delivery: Provides output pressure up to 7 kg/cm2, supporting multi-GC setups while maintaining uniform flow rates under varying laboratory loads.
- Integrated Multi-Stage Filtration: Equipped with ultrafine dust, moisture, oil, and hydrocarbon removal filters, including 0.01 µm filtration, ensuring gas-tight integrity and contaminant-free output.
- Compact & Robust Design: Space-efficient system constructed with high-grade components, optimized for continuous performance with minimal maintenance.
Applications
Microbiology & Culture Growth
Pharma & QC Testing
Food & Water Testing
Research & Academic Labs
Clinical & Diagnostic Labs
Product Models & Specifications
|
Model Name |
Capacity | Chamber Size (cm) | Power | Shelves |
|---|---|---|---|---|
|
ATBAI-1 S/G |
45 L |
35 × 35 × 35 |
300 W |
2 |
|
ATBAI-2 S/G |
90 L |
45 × 45 × 45 |
400 W |
3 |
|
ATBAI-3 S/G |
120 L |
45 × 45 × 60 |
750 W |
3 |
|
ATBAI-4 S/G |
220 L |
60 × 60 × 60 |
1000 W |
3 |
|
ATBAI-5 S/G |
250 L |
60 × 45 × 90 |
1250 W |
3 |
|
ATBAI-6 S/G |
325 L |
60 × 60 × 90 |
1500 W |
4 |
Analytical & Industrial Use
- Petrochemical and refinery labs
- Environmental monitoring agencies
- Pharmaceutical R&D, QC
- Material science & advanced research
Additional Technical Highlights
Capacity Range
100 ml/min to 10,000 ml/min (custom options available)
Purity
99.999% – 99.9995%
Oxygen Content
< 5 ppm
Moisture Content
< 2 ppm
Particle Filtration
0.01 µm
Output Pressure
Upto 7 kg/cm2
Technology
PSA with fully regenerative columns
Electrical Supply
220V AC, 1-phase, 50 Hz
Noise Level
55 – 60 dB
Why Choose Athena’s Bacteriological Incubators?
Precision Engineered
Designed specifically for GC applications requiring stable, high-purity nitrogen.
Continuous & Reliable Supply
Ensures uninterrupted nitrogen availability for long-duration testing.
Customizable Configurations
Available in multiple flows, pressures, and integration options.
Global Support
Athena provides technical assistance through video, phone, or on-site support for institutional installations.
Cylinder-Free Operation
Eliminates handling risks, storage issues, and recurring cylinder costs.
Cost-Efficient
Significant long-term savings versus cylinder-based systems.
1-Year Manufacturer’s Warranty
Covers manufacturing defects and performance reliability.