Products

Zero Air Generator for GC

High-Purity Zero Air System for Gas Chromatography Applications

Athena Instruments introduces the Zero Air Generator for GC, a robust and precision-engineered gas generation system specifically designed for the continuous production of hydrocarbon-free Zero Air for analytical and laboratory applications. Engineered using advanced Pressure Swing Adsorption (PSA) technology combined with a high-efficiency catalytic oxidation chamber, the system ensures total hydrocarbon levels below 0.05 ppm-delivering exceptional analytical stability and detector sensitivity across industries including pharmaceuticals, petrochemicals, environmental testing, research laboratories, and industrial quality control facilities.

Available in laboratory-grade configurations with optimized flow capacity, the Zero Air Generator is extensively tested to ensure stable pressure output up to 80 to 100 psig and consistent performance under continuous 24×7 operating conditions. Manufactured under ISO 9001:2015 certified processes and compliant with CE standards, the system ensures global quality compliance, operational safety, and long-term reliability.

Key Features :

Applications

Gas Chromatography

Reliable combustion air supply for GC-FID, GC-FPD, GC-NPD, GC-TCD, GC-AED, and GC-ELSD systems.

Advanced Analytical Instruments

Suitable for GC-MS, LC-MS/MS, ICP, NMR, FTIR, and IR applications.

TOC Analysis

Ideal for laboratory and online Total Organic Carbon analyzers requiring hydrocarbon-free air.

Industrial & Laboratory Processes

Used for purging systems, ampule filling, turbo evaporators, and analytical-grade air supply applications.

Product Models & Specifications

Model Name

Flow Rate

Total Hydrocarbon Pressure Rating Dew Point Outlet Size
ATZ-02 200 ml/min <0.05 ppm 85 psig (6.5–7 bar) -60°C 1/8” OD
ATZ-05 500 ml/min

<0.05 ppm

85 psig (6.5–7 bar)

-60°C

1/8” OD

ATZ-01 1000 ml/min

<0.05 ppm

85 psig (6.5–7 bar)

-60°C

1/8” OD

ATZ-2 2000 ml/min

<0.05 ppm

85 psig (6.5–7 bar)

-60°C

1/8” OD

ATZ-5 5000 ml/min

<0.05 ppm

85 psig (6.5–7 bar)

-60°C

1/8” OD

ATZ-10 10000 ml/min

<0.05 ppm

85 psig (6.5–7 bar)

-60°C

1/8” OD

Additional Technical Highlights

check-mark

Purification Method

Pressure Swing Adsorption (PSA) with catalytic oxidation processing

check-mark

Flow Capacity

0-10000 ml/min continuous output (Customized as per your requirement)

check-mark

Hydrocarbon Removal Efficiency

<0.05 ppm THC after catalytic chamber

check-mark

Moisture Control

Integrated desiccant air dryer with moisture separator

check-mark

Air Filtration

Multi-stage coalescing filtration system

check-mark

Operating Mode

Fully automatic, continuous 24-hour duty cycle

check-mark

Installation

Plug-and-play configuration for laboratory use

check-mark

Compliance

CE certified and ISO 9001:2015 compliant manufacturing

Why Choose Athena’s Zero Air Generator?

Precision Performance

Ensures accurate and contamination-free combustion air for sensitive GC detectors.

Built for Reliability

Designed for long-term continuous laboratory operation.

Enhanced Safety

Eliminates dependency on high-pressure air cylinders and associated storage risks.

Cost Efficiency

Reduces recurring gas procurement and operational downtime.

Laboratory Versatility

Compatible with multiple GC and analytical instrument platforms.

Backed by Warranty

Includes a 1-Year Manufacturer’s Warranty covering manufacturing defects and performance issues.

Global Support

Supported by Athena’s responsive technical assistance via video, phone, or on-site service for critical installations.

Trusted Performance, Certified Quality

Athena’s Zero Air Generators are CE certified and ISO 9001:2015 compliant, manufactured under stringent in-house quality protocols-delivering laboratory-ready reliability with international safety and quality assurance standards.

Need help finding a solution?

    Products

    Zero Air Generator for GC

    High-Purity Zero Air System for Gas Chromatography Applications

    Athena Instruments introduces the Zero Air Generator for GC, a robust and precision-engineered gas generation system specifically designed for the continuous production of hydrocarbon-free Zero Air for analytical and laboratory applications. Engineered using advanced Pressure Swing Adsorption (PSA) technology combined with a high-efficiency catalytic oxidation chamber, the system ensures total hydrocarbon levels below 0.05 ppm-delivering exceptional analytical stability and detector sensitivity across industries including pharmaceuticals, petrochemicals, environmental testing, research laboratories, and industrial quality control facilities.

    Available in laboratory-grade configurations with optimized flow capacity, the Zero Air Generator is extensively tested to ensure stable pressure output up to 80 to 100 psig and consistent performance under continuous 24×7 operating conditions. Manufactured under ISO 9001:2015 certified processes and compliant with CE standards, the system ensures global quality compliance, operational safety, and long-term reliability.

    Key Features :

    Applications

    Gas Chromatography

    Reliable combustion air supply for GC-FID, GC-FPD, GC-NPD, GC-TCD, GC-AED, and GC-ELSD systems.

    Advanced Analytical Instruments

    Suitable for GC-MS, LC-MS/MS, ICP, NMR, FTIR, and IR applications.

    TOC Analysis

    Ideal for laboratory and online Total Organic Carbon analyzers requiring hydrocarbon-free air.

    Industrial & Laboratory Processes

    Used for purging systems, ampule filling, turbo evaporators, and analytical-grade air supply applications.

    Product Models & Specifications

    Model Name

    Flow Rate

    Total Hydrocarbon Pressure Rating Dew Point Outlet Size
    ATZ-02 200 ml/min <0.05 ppm 85 psig (6.5–7 bar) -60°C 1/8” OD
    ATZ-05 500 ml/min

    <0.05 ppm

    85 psig (6.5–7 bar)

    -60°C

    1/8” OD

    ATZ-01 1000 ml/min

    <0.05 ppm

    85 psig (6.5–7 bar)

    -60°C

    1/8” OD

    ATZ-2 2000 ml/min

    <0.05 ppm

    85 psig (6.5–7 bar)

    -60°C

    1/8” OD

    ATZ-5 5000 ml/min

    <0.05 ppm

    85 psig (6.5–7 bar)

    -60°C

    1/8” OD

    ATZ-10 10000 ml/min

    <0.05 ppm

    85 psig (6.5–7 bar)

    -60°C

    1/8” OD

    Additional Technical Highlights

    check-mark

    Purification Method

    Pressure Swing Adsorption (PSA) with catalytic oxidation processing

    check-mark

    Flow Capacity

    0-10000 ml/min continuous output (Customized as per your requirement)

    check-mark

    Hydrocarbon Removal Efficiency

    <0.05 ppm THC after catalytic chamber

    check-mark

    Moisture Control

    Integrated desiccant air dryer with moisture separator

    check-mark

    Air Filtration

    Multi-stage coalescing filtration system

    check-mark

    Operating Mode

    Fully automatic, continuous 24-hour duty cycle

    check-mark

    Installation

    Plug-and-play configuration for laboratory use

    check-mark

    Compliance

    CE certified and ISO 9001:2015 compliant manufacturing

    Why Choose Athena’s Zero Air Generator?

    Precision Performance

    Ensures accurate and contamination-free combustion air for sensitive GC detectors.

    Built for Reliability

    Designed for long-term continuous laboratory operation.

    Enhanced Safety

    Eliminates dependency on high-pressure air cylinders and associated storage risks.

    Cost Efficiency

    Reduces recurring gas procurement and operational downtime.

    Laboratory Versatility

    Compatible with multiple GC and analytical instrument platforms.

    Backed by Warranty

    Includes a 1-Year Manufacturer’s Warranty covering manufacturing defects and performance issues.

    Global Support

    Supported by Athena’s responsive technical assistance via video, phone, or on-site service for critical installations.

    Trusted Performance, Certified Quality

    Athena’s Zero Air Generators are CE certified and ISO 9001:2015 compliant, manufactured under stringent in-house quality protocols-delivering laboratory-ready reliability with international safety and quality assurance standards.

    Need help finding a solution?